Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/123456789/85
Τύπος: | Ανακοίνωση σε συνέδριο |
Τίτλος: | TL measurements of in-vitro and in-vivo aged feldspathic porcelain |
Συγγραφέας: | [EL] Σφάμπα, Ιωάννα[EN] Sfampa, Ioanna [EL] Μαλλετζίδου, Λαμπρινή[EN] Malletzidou, Lamprini [EL] Παντολέων, Παναγιώτης[EN] Pandoleon, Panagiotis [EL] Κίτης, Γεώργιος[EN] Kitis,George |
Ημερομηνία: | 14/09/2018 |
Περίληψη: | Radiative accidents, led to the birth of an area in physics, accidental dosimetry. Thermoluminescence (TL) is a basic application tool in radiation dosimetry. A special branch of the latter is retrospective dosimetry. Its main application is οn the determination of absorbed dose due to a radiation accident or other event, over and above the normal background radiation. Several materials have been studied as potential accidental dosimeters [1]. The attention is now on materials which can be found anywhere, such as commercial salt, but also on materials that are probable to be found on a person, such as mobiles, or even assembled in a person, like biomaterials which are widely used in surgical and dentistry applications [2]. Feldspathic porcelain (FP) has been widely used in dentistry and is the most applied material as veneer layer in metal-ceramic restorations. The aim of the present work is to prove this material as a personal dosimeter. For this purpose, freshly prepared samples and in-vitro aged were examined, and the measurements were also applied in samples collected from patients. The majority of relevant scientific works are referred only to laboratory prepared samples [3]. It is a unique experiment that aims to compare in-vitro and in-vivo aged samples and their dosimetric properties. Additionally, characterization analysis (FTIR, XRD, SEM-EDS) was applied to every step of the aging, in order to examine if TL can be established as a characterization method of the aging progress of FP. The preliminary thermoluminescence measurements on FP show that the glow curve is consisted basically of two glow peaks. The first one is a low temperature peak around 100 °C and the other one is a high temperature peak at 245 °C. The high temperature peak seems to be suitable for dosimetric applications, while the low temperature peak is suitable for estimating the time elapsed from the end of irradiation (medical irradiation or accident with ionizing irradiation). Keywords: Thermoluminescence, Feldspathic Porcelain, Dosimetry, Characterization |
Γλώσσα: | Αγγλικά |
Τόπος δημοσίευσης: | Prague, Czech Republic |
Σελίδες: | 1 |
ISSN: | 1350-4487 |
Θεματική κατηγορία: | [EL] Ατομική, Μοριακή και Χημική Φυσική[EN] Atomic, Molecular and Chemical Physics |
Κάτοχος πνευματικών δικαιωμάτων: | © 2020 Elsevier B.V. All rights reserved |
Ηλεκτρονική διεύθυνση του τεκμηρίου στον εκδότη: | https://www.sciencedirect.com/journal/radiation-measurements/special-issue/10L0NL32T4T |
Ηλεκτρονική διεύθυνση περιοδικού: | https://www.sciencedirect.com/journal/radiation-measurements |
Τίτλος πηγής δημοσίευσης: | The 10th International Conference on Luminescent Detectors and Transformers of Ionizing Radiation (LUMDETR 2018) |
Όνομα εκδήλωσης: | The 10th International Conference on Luminescent Detectors and Transformers of Ionizing Radiation (LUMDETR 2018) |
Τοποθεσία εκδήλωσης: | Prague, Czech Republic |
Ημ/νία έναρξης εκδήλωσης: | 09/09/2018 |
Ημ/νία λήξης εκδήλωσης: | 14/09/2018 |
Σημειώσεις: | Abstracts are sorted according to the program. |
Εμφανίζεται στις συλλογές: | Ερευνητικές ομάδες |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Σελίδες | Μέγεθος | Μορφότυπος | Έκδοση | Άδεια | |
---|---|---|---|---|---|---|---|
book of abstracts porcelain.pdf | 912.09 kB | Adobe PDF | - | Δείτε/ανοίξτε |